Safety, maximum availability and economic viability in server parks, data centers and IT rooms are now a MUST and require a fault-free power supply. The supplied medium voltage is transformed down to 400 V in the transformer stations and fed to the data center via cable bars or busbars and the low-voltage main distribution board and normal system sub-distribution panel. The normal system sub-distribution panel also provides the uninterruptible power supply (UPS) with electricity. The power supply is permanently monitored by Bender AC/DC sensitive and multi-channel ground-fault monitoring systems. This avoids fire hazards, operational interruptions, functional problems damage and, in the worst-case scenario, data loss as a result of faulty electrical insulation or EMC influence. Bender monitoring systems protect your data every day. Possible risks are recognized early before problems arise. Power quality is the perfect solution for monitoring of low-voltage main distribution boards. Monitoring of the central grounding points via an RCMS guarantees that there is only one connection between N and PE in line with the standards.
The connection between the low-voltage main distribution board and the sub-distribution panels is via busbar systems in order to guarantee the supply is as fault-free as possible. Power quality and RCMS residual current monitoring systems (ground-fault monitors) help with this monitoring.
Electricity providers are not always able to guarantee perfect supply of electrical energies everywhere. Short interruptions or sustained power outages must be bridged by emergency power systems in order to maintain the operation of a data center, including the associated technical systems, such as air-conditioning, electricity and security. The Bender solutions control the changeover and monitor the emergency power system for electrical faults.
An uninterruptible power supply (UPS) is used to ensure the supply of critical electrical loads in the event of problems in the power supply. The UPS systems (normally battery or oscillating weight systems) bridge the period until the emergency power systems (generators) are activated or the system is available again. Electrical safety is continuously monitored by Bender products.
Name | Category | Size | Language | Timestamp | D-/B-Number |
---|---|---|---|---|---|
Product Overview ISOMETER®/ISOSCAN® | Product Overviews | 5.3 MB | EN | 2024/02/1616.02.2024 | |
Product Overview - Residual Current Monitoring | Product Overviews | 6.3 MB | EN | 2024/10/2929.10.2024 | |
Power Quality | Flyers | 468.0 KB | EN | 2022/12/1414.12.2022 | |
Data Centres | Market Segment Brochures | 2.1 MB | EN | 2023/06/1616.06.2023 | |
DATEV eG Achieves Higher Data Center Availability and Reduces Downtime Through the Application of Bender Residual Current Monitoring Technology | Technical Information | 913.0 KB | EN | 2019/05/1313.05.2019 | |
The Future Needs Safety | Technical Article | 456.9 KB | EN | 2019/05/1313.05.2019 | |
Construction of a New Computer Centre | Technical Article | 392.9 KB | EN | 2019/05/1313.05.2019 | |
Bender Protects High-Availability Building Installations | Technical Article | 368.9 KB | EN | 2019/05/1313.05.2019 |
Products
Ground-fault monitoring device for ungrounded AC/DC control circuits
Ground-fault detector for ungrounded AC/DC systems
Multi-channel AC/DC ground-fault monitor
Multi-channel AC/DC ground-fault monitor with individual relay outputs
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor
Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor with one alarm contact per channel
AC/DC sensitive measuring current transformer (Type B)
Recognizing connections – optimizing maintenance
Extension of the nominal voltage range of ISOMETER® iso685.../IR420-D64 series to AC 0...12 kV
Extension of the nominal voltage range of ISOMETER® to AC 0...7200 V
Extension of the nominal voltage range of ISOMETER® iso685… series to AC 0…1150 V, DC 0…1760 V
Extension of the nominal voltage range of ISOMETER® iso685 series to AC, 3(N)AC 0...1650/0...1300 V
Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding
Ground-fault monitoring device for ungrounded AC/DC control circuits
Ground-fault detector for ungrounded AC/DC systems
Multi-channel AC/DC ground-fault monitor
Multi-channel AC/DC ground-fault monitor with individual relay outputs
Four-channel DC, AC and pulse current sensitive residual current monitor for earthed AC, AC/DC and DC systems
Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor
Multichannel AC, pulsed DC and AC/DC sensitive ground-fault monitor with one alarm contact per channel
AC/DC sensitive measuring current transformer (Type B)
Recognizing connections – optimizing maintenance
Extension of the nominal voltage range of ISOMETER® iso685.../IR420-D64 series to AC 0...12 kV
Extension of the nominal voltage range of ISOMETER® to AC 0...7200 V
Extension of the nominal voltage range of ISOMETER® iso685… series to AC 0…1150 V, DC 0…1760 V
Extension of the nominal voltage range of ISOMETER® iso685 series to AC, 3(N)AC 0...1650/0...1300 V
Universal measuring device with numerous measured quantities, energy and power measurement with storage, Power Quality Monitoring, limit value monitoring with alarm forwarding
Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
Errichten von Niederspannungsanlagen - Teil 7-731: Anforderungen für Betriebsstätten, Räume und Anlagen besonderer Art – Abgeschlossene elektrische Betriebsstätten
Environmental Engineering (EE); Earthing and bonding of 400 VDC Data and Telecom (ICT) Equipment - Erdung und Potentialausgleich von Einrichtungen der Informations- und Kommunikationstechnik mit DC 400 V in Rechenzentren und in Betriebsgebäuden der Telekommunikationstechnik (Anerkennung der Englischen Fassung EN 301 605 V1.1.1 (2013-10) als Deutsche Norm)