ISOMETER® IR155 03/04 Series

  • Ground-fault monitoring device (IMD) for ungrounded DC drive systems (IT systems) in electric vehicles
  • Continuous measurement of the insulation resistance 0…10 MΩ, factory-set preconfigured response values
  • AC and DC IT systems up to 0…1000 V
  • Short-circuit protected driver outputs for fault detection and PWM coded Iso measuring value
  • Power supply suitable for 12 V and 24 V systems

The ISOMETER® iso-F1 IR155-3203/-3204 monitors the insulation resistance between the insulated and active HV-conductors of an electrical drive system (Un = DC 0 V…1000 V) and the reference ground (chassis ground > Kl.31). The patented measurement technology is used to monitor the condition of the insulation on the DC side as well as on the AC motor side of the electrical drive system. Existing ground faults will be signalized reliably even under high system interferences which can be caused by motor control processes, accelerating, energy recovering etc.

Questions? Contact us!

ISOMETER® IR155
ISOMETER® IR155
  • Ground-fault monitoring device (IMD) for ungrounded DC drive systems (IT systems) in electric vehicles
  • Continuous measurement of the insulation resistance 0…10 MΩ, factory-set preconfigured response values
  • AC and DC IT systems up to 0…1000 V
  • Short-circuit protected driver outputs for fault detection and PWM coded Iso measuring value
  • Power supply suitable for 12 V and 24 V systems

The ISOMETER® iso-F1 IR155-3203/-3204 monitors the insulation resistance between the insulated and active HV-conductors of an electrical drive system (Un = DC 0 V…1000 V) and the reference ground (chassis ground > Kl.31). The patented measurement technology is used to monitor the condition of the insulation on the DC side as well as on the AC motor side of the electrical drive system. Existing ground faults will be signalized reliably even under high system interferences which can be caused by motor control processes, accelerating, energy recovering etc.

Questions? Contact us!

Features

  • Suitable for 12 V and 24 V systems
  • Automatic device self test
  • Continuous measurement of the insulation resistance 0…10 MΩ
    – Response time for the first measurement of the system state (SST), < 2 s after switching the supply voltage on
    – Response time < 20 s for insulation resistance measurement (DCP)
  • Automatic adaptation to the existing system leakage capacitance (≤1 μF)
  • Detection of ground faults and interruption of the ground connection
  • Insulation monitoring of AC and DC insulation faults for ungrounded systems (IT systems) 0…1000 V
  • Undervoltage detection for voltages below 500 V (adjustable at factory by Bender)
  • Short-circuit proof outputs for:
    – Fault detection (high-side output)
    – Measured value (PWM 5…95 %) and status (f = 10…50 Hz) at high or inverted low-side driver (MHS/MLS output)
  • Protective coating (SL 1307 FLZ)

Applications

  • Monitoring for ungrounded DC drive systems (IT systems) in electric vehicles

ISOMETER® IR155 03/04 Series Variant(s)

Type Art.No
IR155-3203Fixed default parameters
Ran: 100 kΩ
Under voltage detection: 300 V
Fave: 10
Measurement output low side
B91068138V4
IR155-3203Parameters can be customized
Ran: 100 kΩ…1 MΩ
Under voltage detection: 0 V…500 V
Fave: 1…10
Measurement output low side
B91068138CV4
IR155-3204Fixed default parameters
Ran: 100 kΩ
Under voltage detection: 0 V (inactive)
Fave: 10
Measurement output high side
B91068139V4
IR155-3204Parameters can be customized
Ran: 100 kΩ…1 MΩ
Under voltage detection: 0 V…500 V
Fave: 1…10
Measurement output high side
B91068139CV4

Optional Accessories for ISOMETER® IR155 03/04 Series

TypeArt. No
Mounting kitB91068500
Connecting kit IR155-32xxB91068501

Downloads for ISOMETER® IR155 03/04 Series

NameCategorySizeLanguageTimestampD-/B-Number
We are your eMobility partner! Flyers 262.3 KB 2023/11/2929.11.2023
IR155-32xx CE Declarations of Conformity 83.9 KB 2022/08/1212.08.2022
IR155-3203/IR155-3204 Datasheets 481.0 KB EN2024/06/1717.06.2024D00115
IR155-xx03/IR155-xx04 Quickstarts 1.8 MB EN2024/05/2323.05.2024D00115